+86 139 2552 1330 sales@cx-solenoid.com Dongguan, Guangdong, China
Engineering response within 2 working days
Application

Solenoids for Smart Locks & Access Control

Electronic deadbolts, cabinet and drawer locks, access-control strikes, electric rim locks, turnstile and gate locks, alarm contacts and safe locks. The constraint is almost always energy: a latching or low-duty solenoid that opens reliably on a 150 ms pulse and holds without drawing current.

Smart door lock with solenoid-driven latch
Application reference

The constraints that decide the design

Action requiredBolt retract of 3–8 mm against spring preload
Space limitOften under 25 mm of internal depth
Power budgetPulse only; holding current must be zero
Typical choiceLatching solenoid or permanent-magnet lock

Typical requirements

These are the ranges that come up most often in enquiries for this application. They are a starting point for discussion, not a specification — the numbers that matter are the ones from your mechanism.

LatchingLow powerFail-secure

Trade-offs you will have to make

Force against package size

Doubling the force in the same envelope usually means a larger coil and more heat. If the space is fixed, the honest answer is sometimes a different mechanism.

Speed against noise

A faster actuation is louder. End-stop damping, a softer return spring or a reduced drive voltage all trade response time for acoustic performance.

Cost against cycle life

Bearing surfaces, plunger coating and spring quality set the life. These are the first things a low-cost quote removes.

Simplicity against diagnostics

A feedback switch adds cost and a wire, but tells the controller the bolt actually moved. Without it, "locked" is an assumption.

Models used in this application

U0835 open-frame solenoid, studio photo

U0835L-12C13

Rectangular Push-Pull Solenoid

Strokeup to 8 mm Voltage12 V DC
U1253 open-frame solenoid, studio photo

U1253L/S

Compact Open-Frame Push-Pull Solenoid

Strokeup to 10 mm (curve range) VoltageCustom at order (typ. 12 / 24 V DC)
Latching solenoid, KS series

X40180

Square Latching Solenoid

Stroke4 mm Voltage6 / 12 V DC
KS1139 double-latching solenoid, actual product

KS1139L/S

Bi-Directional Latching Solenoid

Stroke5 mm curve range Voltage—
Solenoid for door lock, actual product

X1010L

Cabinet Lock Solenoid, 5 V

Stroke3 mm Voltage5 V DC
KS0521L/S catalogue product photo

KS0521L/S

Bi-stable latching KS0521L/S

Stroke— Voltage—
KS1225L/S catalogue product photo

KS1225L/S

Bi-stable latching KS1225L/S

Stroke— Voltage—
KS1564L/S catalogue product photo

KS1564L/S

Bi-stable latching KS1564L/S

Stroke— Voltage—
KS1895L/S catalogue product photo

KS1895L/S

Bi-stable latching KS1895L/S

Stroke— Voltage—
U0316L/S catalogue product photo

U0316L/S

Open-frame U0316L/S

Stroke— Voltage—
U0415L/S catalogue product photo

U0415L/S

Open-frame U0415L/S

Stroke— Voltage—
U0420 open-frame solenoid, studio photo

U0420L/S

Open-frame U0420L/S

Stroke— Voltage—
U0421L/S catalogue product photo

U0421L/S

Open-frame U0421L/S

Stroke— Voltage—
U0436L/S catalogue product photo

U0436L/S

Open-frame U0436L/S

Stroke— Voltage—
Push-pull solenoid

U0520L/S

Open-frame U0520L/S

Stroke— Voltage—
U0630 open-frame solenoid, studio photo

U0630L/S

Open-frame U0630L/S

Stroke— Voltage—
U0730 open-frame solenoid, studio photo

U0730L/S

Open-frame U0730L/S

Stroke— Voltage—
Push-pull solenoid

U0834L/S

Open-frame U0834L/S

Stroke— Voltage—
U0837 open-frame solenoid, studio photo

U0837L/S

Open-frame U0837L/S

Stroke— Voltage—
U0854 open-frame solenoid, studio photo

U0854L/S

Open-frame U0854L/S

Stroke— Voltage—
U0946 open-frame solenoid, studio photo

U0946L/S

Open-frame U0946L/S

Stroke— Voltage—
U1040 open-frame solenoid, studio photo

U1040L/S

Open-frame U1040L/S

Stroke— Voltage—
Push-pull solenoid

U1146L/S

Open-frame U1146L/S

Stroke— Voltage—
U1245 open-frame solenoid, studio photo

U1245L/S

Open-frame U1245L/S

Stroke— Voltage—
U1564 open-frame solenoid, studio photo

U1564L/S

Open-frame U1564L/S

Stroke— Voltage—
U1847L/S catalogue product photo

U1847L/S

Open-frame U1847L/S

Stroke— Voltage—
Push-pull solenoid

U2244L/S

Open-frame U2244L/S

Stroke— Voltage—
Push-pull solenoid

U30120L/S

Open-frame U30120L/S

Stroke— Voltage—
KY0730L/S catalogue product photo

KY0730L/S

Self-holding KY0730L/S

Stroke— Voltage—
KY0735L/S catalogue product photo

KY0735L/S

Self-holding KY0735L/S

Stroke— Voltage—
KY0940L/S catalogue product photo

KY0940L/S

Self-holding KY0940L/S

Stroke— Voltage—
KY0951L/S catalogue product photo

KY0951L/S

Self-holding KY0951L/S

Stroke— Voltage—
KY1037L/S catalogue product photo

KY1037L/S

Self-holding KY1037L/S

Stroke— Voltage—

How to validate before you commit

  1. Test at the real temperature. A solenoid that pulls 30 N cold may pull 22 N at 60 °C ambient after an hour of operation.
  2. Test with the real load. Springs, friction and off-axis loads all sit between the datasheet and the mechanism.
  3. Run the duty cycle, not one shot. Ten operations prove it moves. Two thousand prove it survives.
  4. Measure the end stop. Impact energy at the end of stroke is what wears plungers and seats.
  5. Keep the batch record. If a unit behaves differently six months later, the test data is the only way to find out why.

Related case study

Locker systems

Battery-powered parcel locker: 8 mm bolt throw on a 150 ms pulse

Continuous holding current of 180 mA flattened a 4 Ah battery in 19 days.

Samples 3 roundsValidation 200k cyclesStatus In production

Common questions

What stroke do I need for a lock bolt?

Enough to clear the strike plate under load, plus 1–2 mm of margin. Most cabinet and locker bolts land between 5 and 12 mm; electronic deadbolts are often 3–8 mm. Measure the worst-case mechanical clearance, not the nominal.

Can it work on battery power?

Yes, if the holding state draws no current. A latching design holds magnetically after a short pulse, so the energy per operation is the pulse only. A spring-return design that stays energised will flatten a small battery in weeks.

What happens when power is lost?

That is a design decision, not a solenoid property. Fail-secure holds the door locked with no power; fail-safe releases it. Latching types can be built either way, and both usually need a mechanical release for service access.

How many cycles can I expect?

It depends on load, stroke and the impact at the end stop — a number without those conditions is marketing. Ask for the cycle test report with the load and stroke stated.

Designing a smart locks & access control product?

Send the mechanism constraints and an engineer will propose a type, a coil and a sample plan.