Locker systemsCustom design
The constraint
Continuous holding current of 180 mA flattened a 4 Ah battery in 19 days.
What we changed
Moved to a bi-stable latching solenoid with a 60 ms drive pulse and a wider bolt throw.
Result
Holding current removed entirely; battery life target extended to 12 months.
Client identity withheld at their request. Test conditions and measured values are as recorded in the project file; they apply to the configuration described and should not be read as a general specification.