Solenoid Duty Cycle and Maximum On-Time

Duty cycle decides whether a solenoid survives or cooks. How to calculate it, what temperature rise to expect, and when to move to a latching design.

Updated 2026-11-23 · 9 min read · Written and reviewed by the Cixin engineering team, Dongguan

Latching solenoid rated for pulsed duty
Pulsed-duty coils are wound for a different thermal life than continuous ones. The frame can look identical.

Duty cycle in plain terms

Duty cycle, sometimes written ED from the German Einschaltdauer, is the fraction of time the coil is energised. A solenoid that runs 2 seconds on and 18 seconds off has a 10 percent duty. The number matters because a coil is, thermally, a small heater with poor cooling. Every second of energisation pumps heat into a winding that can only shed it slowly, and the balance between pumping and shedding decides whether the part lives out its design life or cooks its own insulation.

Two identical-looking solenoids can differ completely in what they survive, purely because their coils were designed for different duty. The frame does not tell you. The coil rating does, and unfortunately some marketplace listings omit it entirely.

Calculating on-time from ED

The arithmetic is simple enough to do in your head, which is why it is worth doing every time rather than trusting a habit. On-time equals duty times total cycle time:

ton = ED × tcycle

A 25 percent duty part on a 40-second cycle may be energised for up to 10 seconds. A 100 percent part, continuous duty, has no limit because the coil is thermally balanced while energised. What people get wrong is not the sum, it is the assumption that a higher duty rating is simply "better". It is not. A continuous-duty coil is wound with more copper and fewer turns, trading force for thermal headroom. For a lock that pulses 200 ms once an hour, a continuous coil is wasted money and a slightly weaker pulse.

Where the heat goes, and the 130 °C ceiling

Coil temperature rise against duty is not linear. Short pulses give the winding time to shed heat between them, so low duty figures are gentle. As duty climbs, the cooling windows shrink and the winding accumulates heat faster than intuition suggests. Measured on one of our standard coils at rated power, 25 °C ambient and still air:

The two bars in orange are the ones that end programs. At 60 percent duty the winding sits 71 °C above ambient; in a machine whose enclosure reaches 45 °C in summer, the winding surface passes 115 °C, which is inside the 130 °C class B insulation limit but with nothing left for voltage tolerance or a clogged fan. At continuous duty the same coil is 88 °C above ambient, and the insulation is living on borrowed time in any warm environment.

Insulation classes give you the ceiling: class A at 105 °C, class B at 130 °C, class F at 155 °C, class H at 180 °C. These are winding temperatures, not ambient ones, and thermal life roughly halves for every 10 °C you run above the class rating. A coil run 20 °C over its class ages about four times faster. Nobody notices on the bench. Everyone notices in year two of the field.

Why maximum on-time matters more than duty

Duty describes a steady rhythm. Real products do not always keep rhythm. A jammed mechanism, a stuck bolt, a control fault, and suddenly the coil has been energised for 30 seconds against a spec that assumed 300 milliseconds. This is the scenario maximum on-time ratings exist for.

For pulsed parts we publish a maximum continuous on-time, typically 5 to 15 seconds for latching and other pulse-rated coils, at rated voltage and a stated ambient. Exceed it and the coil will not fail instantly, but the temperature clock starts running. Good designs pair the pulse rating with driver-side protection: a current cut-off, a watchdog on the MCU, or mechanically a fuse sized to open before the winding does. If your application can physically stall the plunger against a hard load, plan for that stall as a certainty rather than an exception, because in the field it will happen.

Inrush complicates the picture for AC parts and for some DC geometries. The cold coil draws above its steady current for the first tens of milliseconds. That is usually harmless, but if your driver sizes its protection to the steady current, a repeated inrush can nuisance-trip it. The latching guide covers the driver side for pulse designs in more detail.

The derating rules we actually use

When we review a customer's duty spec, we apply three rules that have kept field failure rates low for years. They are conservative, and that is the point.

Rule one: spec the hot coil. Any force figure gets checked at the expected winding temperature, not at 25 °C. See the force vs. stroke article for the size of that correction.

Rule two: halve the datasheet duty if the environment is warm. A coil rated 100 percent in 25 °C still air should be treated as a 50 to 60 percent part inside a 50 °C enclosure with restricted airflow, unless the supplier confirms otherwise with test data for your conditions.

Rule three: the stall case decides the fuse. Size any protective element for the worst plausible stall, not for normal operation. The coil's thermal mass buys seconds; the protection has to act inside them.

How duty claims get tested, honestly

A duty rating is only as good as the test behind it. The setup that produces numbers you can trust is not exotic: the part cycles at rated voltage in a still-air chamber held at the claimed ambient, with a thermocouple on the winding, and the test runs until the winding temperature plateaus. Anything less, for example a bench measurement in open lab air, will overstate the rating by a comfortable margin, because open air flatters the cooling.

We publish the test condition with the rating for exactly this reason. When you compare suppliers, ask each one the same question: at what ambient, with what airflow, measured where on the winding. If the answers differ, the numbers are not comparable, whatever they say on paper. And if a supplier cannot answer, that is an answer too.

For help working through your own cycle, send the on-time, off-time and ambient to the engineering form and we will return a duty and coil recommendation with the reasoning shown.

Frequently asked questions

What does 100% duty cycle mean for a solenoid?

The coil is rated to stay energised continuously at rated voltage in a stated ambient, reaching thermal equilibrium below its insulation class limit. It is wound with a thermal bias, not a pulse bias, and usually delivers less peak force than a pulse-rated coil of the same frame.

How do I calculate duty cycle for my application?

Divide on-time by total cycle time and multiply by 100. A valve opening for 3 seconds every 30 seconds runs 10 percent duty. Use the worst-case rhythm your product can produce, including fault states, not the intended one.

What happens if I exceed a solenoid's duty rating?

Winding temperature climbs past the insulation class limit. Nothing dramatic happens at first; the damage is cumulative. Thermal life roughly halves for every 10 °C above the class rating, so a chronically over-dutied coil fails early, often as an inter-turn short.

Can I improve duty performance without changing the coil?

Lower the holding voltage after pull-in, which cuts heat dramatically for holding applications; improve airflow around the frame; or switch to a latching part that spends no energy holding at all. The third option is usually the honest fix for high-duty holds.