+86 139 2552 1330 sales@cx-solenoid.com Dongguan, Guangdong, China
Engineering response within 2 working days
Product family

Tubular Solenoids

A cylindrical steel housing gives the best force-to-volume ratio at longer strokes. Used in valves, sorting equipment, textile machinery and medical devices.

Tubular linear solenoid

Where this type fits

A cylindrical steel housing gives the best force-to-volume ratio at longer strokes. Used in valves, sorting equipment, textile machinery and medical devices.

13–64 mm
Diameter
10–90 mm
Stroke
5–500 N
Force

How it works

Current through the coil produces a magnetic field that pulls the plunger into the air gap. The useful output is a force that rises steeply as the gap closes — which is why the rated force always belongs to a specific stroke, not to the part in general. Tubular designs trade package size against that force profile in a different way from the other families, and the comparison table below reflects that.

Models in this family

ModelDescriptionStroke / orificeForce / pressureVoltage
T1540L/S 15 mm Tubular Solenoid, 40 mm Body 0–10 mm (curve range) — —
T2530L/S 25 mm Tubular Solenoid, 30 mm Body 0–12 mm (curve range) — —
T6490L/S 64 mm Tubular Solenoid, 90 mm Body 0–12 mm (curve range) — —
T0925L/S Tubular T0925L/S — — —
T1325L/S Tubular T1325L/S — — —
T1340L/S Tubular T1340L/S — — —
T1348L/S Tubular T1348L/S — — —
T1632L/S Tubular T1632L/S — — —
T2070L/S Tubular T2070L/S — — —
T2551L/S Tubular T2551L/S — — —
T2875L/S Tubular T2875L/S — — —
T4577L/S Tubular T4577L/S — — —
T5892L/S Tubular T5892L/S — — —
T6025S Tubular T6025S — — —

What decides the choice

Stroke versus force

Long stroke with high force means a large frame. Fix the stroke first, then see what force is achievable in the space you have.

Duty cycle

Continuous operation needs a coil sized for the temperature rise, not the peak force. Most field failures start here.

Supply and drive

Available voltage, inrush behaviour and whether the drive is a relay, MOSFET or H-bridge all change the coil design.

Environment

Ambient temperature, humidity, dust and vibration determine sealing and insulation class.

What can be customised

  • Coil winding: voltage, resistance, power and insulation class
  • Stroke and force profile for your mechanism
  • Termination: fly leads, PCB pins, connector or terminal block
  • Mounting pattern, plunger end form and return spring
  • Sealing, encapsulation and acoustic damping

Related reading

Have a drawing, a sample, or just a stroke and a force?

Send it over. An engineer reviews every enquiry and replies with a feasible concept, not a brochure.